Skip to content
For research purposes only — not for human consumption. For laboratory and educational reference.

GLP-3(RT)

Retatrutide is a 39-amino-acid synthetic peptide and a triple agonist of the GLP-1, GIP, and glucagon receptors, originally developed by Eli Lilly as LY3437943. It has been studied extensively in metabolic research for its relationship to adiposity, glucose homeostasis, and energy expenditure across both preclinical and phase-trial settings.

Quantity

Wed, Sep 23 - Tue, Sep 29

Free shipment protection

Overnight shipping available

We accept
Apple Pay
Visa
Mastercard
Certificate of analysis
Per-batch verification · documented by lot
Independent7× tested
99.72%
Mean purity
Passed full QC panel
Variant20mg
COA #COA-2026-DGBA3V
Lot #RT20-0726
Labeled20mg
Actual20.93 mg
TestedJul 10, 2026
Full QC panel7× tested
Purity (HPLC)99.79%
Net peptide content20.93
Identity (HPLC)Retatrutide
HPLC conformitymean 99.72%
Heavy metals (ICP-MS)Not Detected
SterilityNo Growth
Endotoxin (USP <85>)< 0.05 EU/mL
ISO/IEC 17025 accredited
LatestIndependent7× tested
99.75%
Mean purity
Passed full QC panel
Variant10mg
COA #COA-2026-DGBA3V
Lot #RT10-0726
Labeled10 mg
Actual10.68
TestedJul 10, 2026
Full QC panel7× tested
Purity (HPLC)99.79%
Net peptide content10.26 mg
Identity (HPLC)Retatrutide
HPLC conformity99.72%
Heavy metals (ICP-MS)Not Detected
SterilityNo Growth
Endotoxin (USP <85>)< 0.05 EU/mL
ISO/IEC 17025 accredited
Independent7× tested
99.46%
Mean purity
Passed full QC panel
Variant30mg
COA #COA-2026-J41LAU
Lot #RT30-0726
Labeled30mg
Actual31.08
TestedJul 5, 2026
Full QC panel7× tested
Purity (HPLC)99.73%
Net peptide content31.08
Identity (HPLC)Retatrutide
HPLC conformityMEAN 99.54%
Heavy metals (ICP-MS)PASS
SterilityPASS
Endotoxin (USP <85>)≤ 0.05 EU/mL
ISO/EIC17025 accredited
View full CoA archive
2381089-83-2
CAS
4731.33 g/mol
Molecular weight
3mL
Vial

What is GLP-3(RT) ?

Metabolic · 10mg, 30mg · 3mL

GLP-3(RT) is a 39-amino-acid synthetic peptide that simultaneously targets the glucagon-like peptide-1 receptor (GLP-1R), the glucose-dependent insulinotropic polypeptide receptor (GIPR), and the glucagon receptor (GCGR). Developed under the designation LY3437943 (Eli Lilly), it has been studied extensively in metabolic research for its relationship to adiposity, glucose homeostasis, and energy expenditure across both preclinical and phase-trial settings. Its triple-receptor profile places it in a distinct category from earlier dual-agonist peptide designs and gives the compound a broader signaling architecture within incretin research. Lyophilized powder, 3mL vial. Sold at 10mg, 20mg, 30mg, and 40mg per vial. For research use only.

39-aa GLP-1R/GIPR/GCGR triple agonist (LY3437943). Eli Lilly.

Identifiers — CAS 2381089-83-2 · C₂₂₁H₃₄₂N₄₆O₆₈ · 4731.33 g/mol · designation LY3437943

Compound Information

Technical specifications

Molecular Profile

What Is GLP-3(RT)?

Type Peptide
CAS Number 2381089-83-2
Molecular Weight 4731.33 g/mol
Amino Acids 39 amino acids
Formula C221H342N46O68
Storage Requirements

Stability Information

  • Lyophilized
  • Protect from light
  • For research use only
  • Lyophilized
    -20°C 24 months (unopened)
  • Reconstituted
    2–8°C Up to 30 days
  • Working solution
    2–8°C Use within 7 days

Product specifications

Technical details

Technical specifications
CAS number
2381089-83-2
Molecular formula
C221H342N46O68
Molecular weight
4731.33 g/mol g/mol
Type
Peptide
Residues / units
39 amino acids
Vial size
3mL
Molecular weight
4731.33 g/mol — Registry verified

Storage & Handling

Storage conditions for unopened vials

LYOPHILIZED
-20°C

Long-term storage. Protect from moisture and light.

RECONSTITUTED
2–8°C

Refrigerate after reconstitution. Do not freeze reconstituted solution unless validated for your protocol.

SHIPPING
Ambient

Lyophilized peptides ship at ambient temperature under normal conditions.

WARNINGS
  • For research use only — not for human or veterinary consumption.
  • Handle with appropriate PPE in a controlled laboratory environment.
  • Confirm form, salt, and concentration against your supplier CoA before use.

Sources & References

Peer-reviewed research

GLP-3(RT) is a 39-amino-acid synthetic peptide and a triple agonist of the GLP-1, GIP, and glucagon receptors, originally developed by Eli Lilly as LY3437943. It has been studied extensively in metabolic research for its relationship to adiposity, glucose homeostasis, and energy expenditure across both preclinical and phase-trial settings. Its triple-receptor profile places it in a distinct category from earlier dual-agonist peptide designs and gives the compound a broader signaling architecture within incretin research. Lyophilized powder, 3mL vial. Sold at 10mg, 20mg, 30mg, and 40mg per vial. For research use only.

All the research peptides you need, with the peace of mind.

Shop Now

Research updates from retaUp

Subscribe for catalog updates, new research compounds, and quality documentation news.

For researchers and labs. No spam, unsubscribe anytime.